Surge protection devices
Transient surges
It is a sudden and high current increase (µs) on
an electricity network, that can reach many kV.
In their majority they are caused by atmospheric
discharges, even if sometimes they are due to
commutations on the network.
They can provoke serious damages and the destruction of the electrical devices,
bad operation and reduction of their estimated life as well as interruption of the
service to users.
All these problems can be eliminated reducing this hard impulse by protective
devices (Vigivolt).
Temporary overvoltages
It can be defi ned as an increase of the network
current, over the 10% of the nominal value for an
indefi nite time, from milliseconds to hours. The
origin is due to the neutral loss or to a failure of
the medium voltage transformer.
As for the transient surges, the temporary overvoltages can cause damages and
the destruction of the electrical devices, their premature aging and loss of safety
for the users.
The devices (Vigivolt) avoid these risks by switching off the power supply, acting
on the main switch.
www.toscano.es
TRANSIENT SURGESTEMPORARY OVERVOLTAGES
SURGE PROTECTION DEVICES
TRANSIENT & TEMPORARY SURGES
THREE PHASESINGLE PHASESINGLE PHASESINGLE PHASETHREE PHASETHREE PHASE
CLASS IIMANUAL RESTARTCLASS II
V2T-30COMBI2P
V2T-60V2POP+MCB
VDUOPOP+IGAV2T-5V2PR-40V3T-100FV-500/2
FV-1000/3
30 KA
240 VACAMPERAGE
25, 40, 50 or 63 A
60 KA
240 VACAMPERAGE
25, 40, 50 or 63 A
15 KA
25, 40, 50 or 63 A5 KA
240 VAC40 A
240 VAC100 KA
400 VAC40 KA
500 VDC
40 KA
1000 VDC
30 KAAMPERAGE
60 KAAMPERAGE
15 KA
V3POP+MCB
AMPERAGE
25, 40, 50 or 63 AAMPERAGE
VTRIOPOP+IGA
15 KA
25, 40, 50 or 63 A15 KA5 KA40 A100 KA
COMBI4P
AMPERAGE
25, 40, 50 or 63 AAMPERAGE40 KA
40 KA
CLASS IMANUAL RESTARTCLASS IICLASS IIIAUTO RESTARTCLASS II
PHOTOVOLTAIC
V3T-50BC
50 KA
400 VAC50 KA
CLASS I+II
V3T-30
V3T-60
30 KA
400 VAC
60 KA
400 VAC
30 KA
60 KA
CLASS II
10002140 V3T-100 3-phase 3P+N 400VAC 100kA I
10002236 V3T-50BC 3-phase 3P+N 400VAC 50kA I+II
10001699 V2T-60 1-phase 1P+N 240VAC 60kA II
10001700 V3T-60 3-phase 3P+N 400VAC 60kA II
10001750 V2T-30 1-phase 1P+N 240VAC 30kA II
10001751 V3T-30 3-phase 3P+N 400VAC 30kA II
10002139 V2T-5 1-phase 1P+N 240VAC 5kA III
10001522 FV-500/2 Photovoltaic surge arrester 500VDC 40kA, with remote signalling II
10001523 FV-1000/3 Photovoltaic surge arrester 1000VDC 40kA, with remote signalling II
PART NO.MODEL TRANSIENT SURGES CLASS
PART NO.MODEL TEMPORARY OVERVOLTAGES
10002241 V2POP+IGA25 1-phase + MCB 2x25A 10kA
10002057 V2POP+IGA40 1-phase + MCB 2x40A 10kA
10002325 V2POP+IGA50 1-phase + MCB 2x50A 10kA
10002326 V2POP+IGA63 1-phase + MCB 2x63A 10kA
10002327 V3POP+IGA25 3-phase + MCB 4x25A 10kA
10002128 V3POP+IGA40 3-phase + MCB 4x40A 10kA
10002328 V3POP+IGA50 3-phase + MCB 4x50A 10kA
10002242 V3POP+IGA63 3-phase + MCB 4x63A 10kA
10002219 V2PR40 1-phase 240VAC 40A resettable
MISC. COMBI 2Pxx 1-phase + MCB 2x25, 40, 50 or 63A 10kA
MISC. COMBI 4Pxx 3-phase + MCB 4x25, 40, 50 or 63A 10kA
PART NO. MODEL TRANSIENT & TEMPORARY SURGES
10002233 DUOPOP+IGA25 1-phase 15kA + MCB 2x25A 10kA
10002063 DUOPOP+IGA40 1-phase 15kA + MCB 2x40A 10kA
10002329 DUOPOP+IGA50 1-phase 15kA + MCB 2x50A 10kA
10002330 DUOPOP+IGA63 1-phase 15kA + MCB 2x63A 10kA
10002331 TRIOPOP+IGA25 3-phase 15kA + MCB 4x25A 10kA
10002131 TRIOPOP+IGA40 3-phase 15kA + MCB 4x40A 10kA
10002332 TRIOPOP+IGA50 3-phase 15kA + MCB 4x50A 10kA
10002244 TRIOPOP+IGA63 3-phase 15kA + MCB 4x63A 10kA
ALL OUR NEW MODELS COMPLY WITH THE EUROPEAN
REGULATIONS ON PROTECTION DEVICES AGAINST
TEMPORARY OVERVOLTAGES.